Triad Magnetics’ Chassis Mount World Series™ Toroidal power transformers are compact transformers that are both cost effective and highly efficient.

Approved to UL 506, CE IEC 61558-1, and CE IEC 615 58-2-6 standards, and constructed with a Class B rated insulation system, approved for operation up to 130ºC, our World Series™ Toroidal power transformers are highly versatile.

World Series™ Toroidal power transformers are manufactured with dual primary coils and dual secondary coils, allowing for a high degree of input and output voltage flexibility. The primary and secondary coils are electrically isolated from each other, and from the core, which helps to minimize stray electric fields and ensure quiet operation.

All of our more than 40 Chassis Mount World Series™ Toroidal power transformers, which range in electrical rating from 25 VA to 2,500 VA, are equipped with leads for each connection.

Read the specification chart below, or contact Triad Magnetics today, to learn more.

Toroidal Mount World Series™ Power Transformers
Unit of Measure
Items Toroidal Mount World Series™ Power Transformers
VPT12-2080
Toroidal Mount World Series™ Power Transformers
Toroidal Mount World Series™ Power Transformers
VPT18-1390
Toroidal Mount World Series™ Power Transformers
Toroidal Mount World Series™ Power Transformers
VPT24-1040
Toroidal Mount World Series™ Power Transformers
Toroidal Mount World Series™ Power Transformers
VPT30-830
Toroidal Mount World Series™ Power Transformers
Toroidal Mount World Series™ Power Transformers
VPT36-690
Toroidal Mount World Series™ Power Transformers
Description N/A Triad chassis mount World Series Toroidal transformers are efficient, compact, cool running and cost effective. They are approved to UL 5085-1 and CE IE C 61558-1 and 615 58-2-6, and are constructed with a Class B (130C) rated insulation system. These toroidal transformers have minimal stray fields for quiet operation around sensitive circuits. The transformers consist dual primaries and dual secondaries which allows for flexibility in the input and output voltages. The primary and secondary are both electrically isolated from each other and from the core itself . Chassis mount Toroidal World Series transformers are available in sizes ranging from 25 VA to 2,500 VA and are equipped with leads for connections.
Click here to check stock >> N/A N/A N/A N/A N/A
Electrical Rating N/A 25 V·A
Secondary Voltage in Series N/A 12 V CT at 2.08 A N/A 18 V CT at 1.39 A N/A 24 V CT at 1.04 A N/A 30 V CT at 0.83 A N/A 36 V CT at 0.69 A
Transformer Contact Type N/A Center Tap
Secondary Voltage in Parallel N/A 6.0 V at 4.16 A N/A 9.0 V at 2.78 A N/A 12 V at 2.08 A N/A 15 V at 1.66 A N/A 18 V at 1.38 A
Typical Regulation N/A 12.0 %
Typical Efficiency N/A 88 %
Outside Diameter N/A 74 mm
Height (H) N/A 34 mm
Weight N/A 0.4 kg
Typical Temperature Rise N/A 30 ºC
Mounting Plate Diameter N/A 55 mm
Rubber Pads Diameter N/A 57 mm
Mounting Hardware N/A M5 x 40 mm
Primary Voltage N/A 115 V230 V
Primary Frequency N/A 50 Hz60 Hz
Industry Standards N/A 615 58-2-6 CE IEC 61558-1 UL 5085-1
Secondary N/A Dual for parallel or series connection
Insulation Class N/A Class B, 130 ºC
Dielectric Isolation (Primary to Secondary) for 60 seconds N/A 4 kV
Technical Notes N/A
  1. Series Connections:
      Input1: Series - BLUE and BROWN, Jumper GRAY to VIOLET
        Parallel - BLUE and BROWN, Jumper BLUE to VIOLET, GRAY to BROWN
      Output1:: Series - BLACK and YELLOW, Jumper RED to ORANGE
        Parallel - BLACK and YELLOW, Jumper BLACK to ORANGE, RED to YELLOW
Note N/A Primary and secondary windings are designed to be connected in series or parallel. Windings are not intended to be used independently. For additional technical information
Nominal Secondary Voltage N/A 6 V12 V N/A 9 V18 V N/A 12 V24 V N/A 15 V30 V N/A 18 V36 V
Secondary Voltage-Series Connection N/A
Secondary Voltage-Parallel Connection N/A
Mounting N/A Transformers are provided with one metal plate, two rubber pads, screw, nut and washer through 1KVA. Epoxied center and drilled hole for VA’s larger than 1kVA. Epoxied center and drilled hole also available for VA’s smaller than 1kVA; minimums may apply.
Connections N/A Stranded UL 1015 leads, stripped and tinned 0.25" (6mm). Standard lead length is 8" (200mm) for VA’s up to and including 250VA; 12.0" (305mm) for 500VA and higher (these are stripped and tinned 0.5" (12.7mm)). Custom lead lengths and other UL types lead wire available; minimums may apply.

Custom designs available.
RoHS Compliance N/A As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU, known as the RoHS 3 initiative.
Additional Information N/A High Efficiency and low stray fields