Triad chassis mount World Series Toroidal transformers are efficient, compact, cool running and cost effective. They are approved to UL 5085-1 and CE IE C 61558-1 and 615 58-2-6, and are constructed with a Class B (130C) rated insulation system. These toroidal transformers have minimal stray fields for quiet operation around sensitive circuits. The transformers consist dual primaries and dual secondaries which allows for flexibility in the input and output voltages. The primary and secondarymore
Unit of Measure

Check Stock

Click here to check stock >>

Specifications

Electrical Rating

25 V·A

Secondary Voltage in Series

30 V CT at 0.83 A

Transformer Contact Type

Center Tap

Secondary Voltage in Parallel

15 V at 1.66 A

Typical Regulation

12.0 %

Typical Efficiency

88 %

Typical Temperature Rise

30 ºC

Height (H)

32 mm

Primary Voltage

115 V230 V

Primary Frequency

50 Hz60 Hz

Industry Standards

615 58-2-6 CE IEC 61558-1 UL 5085-1

Mechanical Specifications

Outside Diameter

71 mm

Weight

0.4 kg

Mounting Plate Diameter

55 mm

Rubber Pads Diameter

57 mm

Mounting Hardware

M5 x 40 mm

Technical Notes

N/A

  1. Series Connections:
      Input1: Series - BLUE and BROWN, Jumper GRAY to VIOLET
        Parallel - BLUE and BROWN, Jumper BLUE to VIOLET, GRAY to BROWN
      Output1:: Series - BLACK and YELLOW, Jumper RED to ORANGE
        Parallel - BLACK and YELLOW, Jumper BLACK to ORANGE, RED to YELLOW

Note

N/A Primary and secondary windings are designed to be connected in series or parallel. Windings are not intended to be used independently. For additional technical information