Triad International Series transformers are constructed with European style split bobbins to meet International safety agency standards. The split bobbin construction reduces interwinding capacitance and eliminates the need for electrostatic shielding.
Available in sizes from 5 VA to 56 VA 115 V / 230 V 50/60 Hz Primary windings; 3,500 V isolation between primary and secondary; designed with 6 mm creepage distance primary to secondary.
Available in sizes from 5 VA to 56 VA 115 V / 230 V 50/60 Hz Primary windings; 3,500 V isolation between primary and secondary; designed with 6 mm creepage distance primary to secondary.
Unit of Measure
Specifications
Electrical Rating |
N/A 56.0 V·A |
Secondary Series Connected |
N/A 28.0 V2.000 A |
Transformer Contact Type |
N/A Center Tap |
Secondary Parallel Connected |
N/A 14.00 V4.000 A |
Center Tap |
N/A Y |
Case Type |
N/A U |
Height (H) |
N/A 3 1/16 in |
Width (W) |
N/A 2 9/16 in |
Depth (D) |
N/A 2 5/8 in |
Mounting Width |
N/A 2 in |
Mounting Depth |
N/A 2 1/4 in |
Primary Voltage |
N/A 115 V230 V |
Primary Frequency |
N/A 50 Hz60 Hz |
Creepage Distance |
N/A 6 mm |
Weight |
N/A 2.70 lb |
Technical Notes
N/A Primary and secondary windings are designed to be connected in Series or Parallel. Windings are not intended to be used independently |