The FP230-10 is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials.
Unit of Measure

Check Stock

Click here to check stock >>

Specifications

Electrical Rating

2.5 V·A

Voltage in Series

230.0 V CT at 0.01 A

Transformer Contact Type

Center Tap

Voltage in Parallel

115.0 V at 0.02 A

Dimension (A)

1.875 in

Dimension (B)

1.562 in

Dimension (C)

0.650 in

Dimension (D)

0.267 in

Dimension (E)

0.375 in

Dimension (F)

1.600 in

Dimension (H)

0.650 in

Dimension (L)

1.875 in

Dimension (W)

1.562 in

Weight

5.0 oz

Pin Dimension

0.020 x 0.041 in

Mounting Width

0.88 in

Mounting Length

1.62 in

Primary Voltage

115 V230 V

Primary Frequency

50 Hz60 Hz

RMS Hi Pot Tested

2,000 V

Construction

Wound on two dual channel nylon bobbin. Materials are UL recognized, Class B (130º C) rated.

Safety

These products are 100% tested for dielectric strength at 2 KVAC, 60 Hz between primary and secondary windings and between the primary/secondary windings and the core.

Agency File

UL: File E53148, UL 506, Class B General Purpose Transformer,
cUL: File E53148, UL 506, Class B General Purpose Transformer, Canadian Use

RoHS Compliance

As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU, known as the RoHS 3 initiative.

Technical Notes

N/A

  1. Hi-pot tested at 2,000 VRMS.
  2. Split bobbin with side-by-side windings to reduce capacitance and eliminate the need for a static shield.
  3. Mounting Holes: 2.5 VA & 6VA = 0.125"; 12 VA = 0.165"; 24 VA = 0.157"; 48 VA = 0.20"