Triad chassis mount World Series transformers are designed to meet U.S. and International standards including CSA, IEC, TUV and UL requirements. The transformers consist of a dual bobbin design positioned inside an insulating shroud and constructed with UL approved high temperature material. This design eliminates the need for electrostatic shielding since there is minimal capacitance between coils when using a dual bobbin configuration. The primary and secondary are both electrically isolatedmore
Unit of Measure

Check Stock

Click here to check stock >>

Specifications

Electrical Rating

80 V·A

Secondary Series

12.6 V CT at 6.3 A

Secondary Parallel

6.3 V at 12.6 A

Transformer Contact Type

Center Tap

Height (H)

3 in

Width (W)

2 1/2 in

Depth (D)

2 5/16 in

Dimension (B)

1 3/8 in

Dimension (C)

5/16 in

Dimension (T)

3/16 in

Mounting Width

2 in

Mounting Length

2 1/4 in

Mounting Hole Size

13/64 x 3/8 in

Primary Voltage

115 V230 V

Primary Frequency

50 Hz60 Hz

Weight

2.80 lb

Technical Notes

N/A

  1. Hi-pot tested at 4,000 VRMS.
  2. Both primary and secondary coils may be connected as either series or parallel, but both must be used simultaneously.