When health and personal wellbeing is at stake, as it often is in medical industry scenarios, it is of the utmost importance that equipment functions properly. Medical machinery equipped with Triad Magnetics’ Medical Grade Isolation power transformers are the ideal solution.

Medical Grade Isolation power transformers from Triad offer a number of benefits over transformers from other manufacturers. Their toroidal construction allows for them to be manufactured in much smaller sizes than standard EI transformers, ranging in heights of 5.12 in to 6.82 in, and improves efficiency.

Constructed within a Class F insulated, white powder coated steel enclosure, our Medical Grade Isolation power transformers are ideal for use with hospital beds, dental chairs and equipment, medical lab equipment, and patient monitoring equipment. Perhaps the most important benefit is that stray fields are greatly reduced, ensuring that the functioning of other sensitive equipment will not be affected.

To learn more, read the specification chart below or contact Triad Magnetics today.

Unit of Measure
Items
Medical Grade Isolation Power Transformers

5.28 Inch (in) Length Medical Grade Isolation Power Transformer

Medical Grade Isolation Power Transformers

5.28 Inch (in) Length Medical Grade Isolation Power Transformer

Medical Grade Isolation Power Transformers

6.38 Inch (in) Length Medical Grade Isolation Power Transformer

Medical Grade Isolation Power Transformers

6.38 Inch (in) Length Medical Grade Isolation Power Transformer

Medical Grade Isolation Power Transformers

7.17 Inch (in) Length Medical Grade Isolation Power Transformer
Description N/A These medical grade isolation boxes are built using a toroidal transformer construction that inherently helps reduce stray fields, increases efficiency and minimizes size compared to traditional EI transformers. Built with Class F (155º) insulation system. The enclosure is made of steel and powder coated white.
Click here to check stock >> N/A N/A N/A N/A N/A
Maximum Power N/A 250 V·A N/A 250 V·A N/A 500 V·A N/A 500 V·A N/A 1000 V·A
Input Voltage1 N/A 240 V N/A 120 V N/A 240 V N/A 120 V N/A 240 V
Output Voltage2 N/A 120 V
Connection Type N/A Cord, Plug & Socket
Safety N/A Medical
Length N/A 5.28 in134 mm N/A 5.28 in134 mm N/A 6.38 in162 mm N/A 6.38 in162 mm N/A 7.17 in182 mm
Width N/A 6.93 in176 mm N/A 6.93 in176 mm N/A 8.23 in209 mm N/A 8.23 in209 mm N/A 9.06 in230 mm
Height N/A 5.12 in130 mm N/A 5.12 in130 mm N/A 5.75 in146 mm N/A 5.75 in146 mm N/A 5.75 in146 mm
Weight N/A 4.0 kg N/A 4.0 kg N/A 5.5 kg N/A 5.5 kg N/A 21 kg
Warranty N/A 5 years
Enclosure Material N/A Steel
Enclosure Finish N/A Powder Coated
Enclosure Color N/A White
Mounting N/A Rubber Feet for Horizontal Mounting.
Input Voltage Tolerance (Power Cord) N/A ±10 %
Frequency (Power Cord) N/A 50 Hz60 Hz
Note for Output Voltage N/A Alternating Current (AC) Output Voltage (Receptacle) at Maximum 2.08 A. N/A Alternating Current (AC) Output Voltage (Receptacle) at Maximum 2.08 A. N/A Alternating Current (AC) Output Voltage (Receptacle) at Maximum 4.35 A. N/A Alternating Current (AC) Output Voltage (Receptacle) at Maximum 4.35 A. N/A Alternating Current (AC) Output Voltage (Receptacle) at Maximum 8.33 A.
Typical Voltage Regulation from Full Load to No Load N/A 8 % N/A 8 % N/A 5 % N/A 5 % N/A 5 %
Alternating Current (AC) Input to Output Voltage (Hi-Pot) N/A 3000 V
Alternating Current (AC) Input and Output to Enclosure Voltage (Ground) (Hi-Pot) N/A 1500 V
Typical Efficiency at Full Load N/A 92 % N/A 92 % N/A 94 % N/A 94 % N/A 94 %
Operating Ambient Temperature N/A Not to Exceed 60 ºC
Leakage Current N/A Less Than 50 µA
Typical Leakage Current N/A 10 µA
Fusing N/A Replace only with 1.8 A, 250 VAC, Slow Blow, UL Listed Fuses. N/A Replace only with 3.0 A, 250 VAC, Slow Blow, UL Listed Fuses. N/A Replace only with 3.0 A, 250 VAC, Slow Blow, UL Listed Fuses. N/A Replace only with 6.0 A, 250 VAC, Slow Blow, UL Listed Fuses. N/A Replace only with 6.0 A, 250 VAC, Slow Blow, UL Listed Fuses.
Input Connections N/A 11 ft. Medical Grade Power Cord with NEMA 6-15P Plug. N/A 11 ft. Medical Grade Power Cord with NEMA 5-15P Plug. N/A 11 ft. Medical Grade Power Cord with NEMA 6-15P Plug. N/A 11 ft. Medical Grade Power Cord with NEMA 5-15P Plug. N/A 11 ft. Medical Grade Power Cord with NEMA 6-15P Plug.
Output Connections N/A Duplex Receptacle. NEMA 5-15R. N/A Duplex Receptacle. NEMA 5-15R. N/A Duplex Receptacle. NEMA 5-15R. N/A Duplex Receptacle. NEMA 5-15P. N/A Duplex Receptacle. NEMA 5-15R.
Insulation Class N/A Class F (155º)
Industry Standards N/A CSA cULus Listed RoHS 2015/863/EU
Note N/A Medical isolation transformer box is certified to UL 60601-1, 2nd edition medical standard and CSA-C22.2.No. 601.1M90, 2005
UL: (E352717), UL60601-1, 2nd edition and CAN/CSA-C22.2 No. 601.1M90, 2005

Not for use in life critical application.
  • 1 Alternating Current (AC) Input Volatge (Power Cord)
  • 2 Combined loads connected to receptacle (s) must not exceed maximum current rating.