Items |
AWSP40-5 AWSP 40 Series - 40 Watt (W) Single Output Enclosed Switching Power Supplies |
AWSP40-12 AWSP 40 Series - 40 Watt (W) Single Output Enclosed Switching Power Supplies |
AWSP40-24 AWSP 40 Series - 40 Watt (W) Single Output Enclosed Switching Power Supplies |
|||
Description | N/A 40 Watt Single Output Enclosed Switching Power Supply for General Purpose Applications | |||||
Click here to check stock >> | N/A | N/A | N/A | |||
Voltage | N/A 5.0 V | N/A 12 V | N/A 24 V | |||
Current | N/A 7.6 A | N/A 3.3 A | N/A 1.7 A | |||
Efficiency | N/A 72 % | N/A 77 % | N/A 80 % | |||
Input Voltage (AC) | N/A 85 to 264 V | |||||
Input Frequency Range | N/A 47 to 63 Hz | |||||
Maximum Input Current | N/A 1.0 A | |||||
Maximum Inrush Current at 110 / 220 VAC (Cold Start) | N/A 20 A40 A | |||||
Minimum Load | N/A No | |||||
Adjustable Output Range | N/A ±10 % | |||||
Ripple/Noise (pk-pk 20MHz) | N/A 5/12/24 V = 75/100/100 mV | |||||
Load Regulation | N/A ±1.0 % | |||||
Line Regulation | N/A ±0.5 % | |||||
Minimum Hold-up Time, 100% Load at 220 VAC | N/A 30 ms | |||||
Maximum Rise-up Time at 220 VAC | N/A 300 ms | |||||
Over Current Protection (Power Cycle Reset) | N/A >120 % | |||||
Over Voltage Protection (Zener Diode) | N/A >110 % | |||||
Switching Frequency | N/A 50 kHz | |||||
Length (L) | N/A 5.08 in129 mm | |||||
Width (W) | N/A 3.86 in98 mm | |||||
Height (H) | N/A 1.50 in38 mm | |||||
Weight | N/A 360 g | |||||
Warranty | N/A 2 years | |||||
Operating Temperature | N/A 0 to +45 ºC Full Load, derate 3.33%/ºC up to 60 ºC | |||||
Storage Temperature | N/A -25 to +75 ºC | |||||
Cooling | N/A Convection Cooled Operation | |||||
Humidity | N/A 10 to 95 % RH, non-condensing | |||||
Vibration | N/A 10 to 55 Hz, 2G 1 min/cycle, period of 60 min, each axis. | |||||
Reliability | N/A >176,000 Hours MTBF | |||||
EMC Emissions | N/A EN55022,VCCI,CISPR22 Class B (Conducted & Radiated); IEC-61000-4-2, 61000-4-4, 61000-4-5, 61000-4-11 | |||||
Safety Approval | N/A UL 60950 (UL File No: E204980) | |||||
Input - Output Dielectric Strength | N/A 3 kVAC / 1 min | |||||
Input - Ground Dielectric Strength | N/A 2.5 kVAC / 1 min | |||||
Output - Ground Insulation Resistance | N/A >100 mOhm / 500 VDC | |||||
Input Terminal | N/A Screw | |||||
Output Terminal | N/A Screw | |||||
|