Print Back
26 Watt Max Constant Current Encapsulated DC/DC Switching Power Supply for Indoor & Outdoor IP66 / NEMA 4 Applications.
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies - 2
Unit of Measure
Items TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLM4036DC-0350-40
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLM4036DC-0350-36
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLM4036DC-0350-32
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLM4036DC-0350-30
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
TLM4036DC-0350-28
TLD40 Series - 26 Watt (W) Max Constant Current Encapsulated DC/DC Switching Power Supplies
Description N/A 26 Watt Max Constant Current Encapsulated DC/DC Switching Power Supply for Indoor & Outdoor IP66 / NEMA 4 Applications.
Click here to check stock >> N/A N/A N/A N/A N/A
Input Voltage (DC) N/A 40 V N/A 36 V N/A 32 V N/A 30 V N/A 28 V
Current N/A 0.350 A
Maximum Power N/A 13.0 W N/A 11.2 W N/A 9.8 W N/A 9.1 W N/A 8.40 W
Adjustable Output Range N/A Fixed
Current Accuracy N/A ±5 %
Short Circuit Protection N/A Auto - Recovery
Output Voltage (DC) N/A 2-36 V N/A 2-32 V N/A 2-28 V N/A 2-26 V N/A 2-24 V
Length (L) N/A 1.26 in32 mm
Width (W) N/A 1.22 in31 mm
Height (H) N/A 0.59 in15 mm
Weight N/A 120 g
Warranty N/A 3 years
Efficiency N/A 90 %
Operating Temperature N/A -40 to +60 ºC Full Load, derate 1%/ºC from 60 to Z570 ºC max ºC
Storage Temperature N/A -40 to +80 ºC
Cooling N/A Convection Cooled Operation
Humidity N/A 5 to 95 % RH, non-condensing
Vibration N/A 5 to 50 Hz, 2G 1 min/cycle, period of 60 min, each axis.
Reliability N/A >100k Hours MTBF (full load & 25 ºC)
Input Wire N/A 18 AWG
Input Leads N/A 5 in