The AEU65-240 is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive.
Unit of Measure
Check Stock
|
Input Characteristics (at 25 ºC)
|
Output Characteristics (at 25 ºC)
|
General Specifications (at 25 ºC)
|
Environmental Specifications (at 25 ºC)
|
EMC and Safety Specifications (at 25 ºC)
|
Specifications
|
Note
|
SnapMagic
Input Characteristics (at 25 ºC)
Alternating Current (AC) Input Voltage |
N/A 90 to 264 V |
Direct Current (DC) Input Voltage |
N/A 127 to 373 V |
Input Frequency Range |
N/A 47 to 63 Hz |
Input Current at 115 VAC (Root Mean Square (RMS)) |
N/A 1.6 A |
Input Current at Typical 230 VAC |
N/A 0.8 A |
Maximum Inrush Current at 115 VAC for Cold Start |
N/A 30 A |
Maximum Inrush Current at 230 VAC for Cold Start |
N/A 60 A |
Leakage Current at 240 VAC |
N/A < 2.4 mA |
Output Characteristics (at 25 ºC)
Direct Current (DC) Output Voltage |
N/A 24 V |
Direct Current (DC) Voltage Tolerance |
N/A ±1.5 % |
Output Current (Convection) |
N/A 0 to 2.71 A |
Output Power (Convection) |
N/A 65 W |
Adjustable Output Voltage Range1 | N/A 22.8 to 25.2 V |
Ripple and Noise Voltage at Peak to Peak2 | N/A 200 mV |
Load Regulation |
N/A ±0.5 % |
Line Regulation |
N/A ±0.5 % |
Efficiency |
N/A 86.5 % |
Start-Up Time at 230 VAC for Full Load |
N/A 1000 ms |
Start-Up Time at 115 VAC for Full Load |
N/A 2000 ms |
Rise-Up Time at 230 VAC for Full Load |
N/A 30 ms |
Rise-Up Time at 115 VAC for Full Load |
N/A 30 ms |
Hold-Up Time at 230 VAC for Full Load |
N/A 24 ms |
Hold-Up Time at 115 VAC for Full Load |
N/A 12 ms |
Overcurrent Protection3 | N/A 110 to 160 % |
Direct Current (DC) Over Voltage Protection |
N/A 27.6 to 32.4 V |
Output Type |
N/A Constant Voltage |
General Specifications (at 25 ºC)
Length |
N/A 110 mm4.3 in |
Width |
N/A 78 mm3.1 in |
Height |
N/A 35.0 mm1.38 in |
Weight |
N/A 200 g |
Cooling |
N/A Natural Convection |
Isolation Resistance at 500 VDC (Input (I/P) - Output (O/P)) |
N/A 100 MO |
Isolation Resistance at 500 VDC (Input (I/P) - Floating Gate (FG)) |
N/A 100 MO |
Isolation Resistance at 500 VDC (Output (O/P) - Floating Gate (FG)) |
N/A 100 MO |
Direct Current (DC) Dielectric Strength (Input (I/P) - Output (O/P)) |
N/A 4.3 kV |
Alternating Current (AC) Dielectric Strength (Input (I/P) - Floating Gate (FG)) |
N/A 1.5 kV |
Alternating Current (AC) Dielectric Strength (Output (O/P) to Floating Gate (FG)) |
N/A 0.5 kV |
Warranty |
N/A 3 years |
Minimum Mean Time Between Failure (MTBF) per MIL-HDBK-217F (25 ºC) |
N/A 250 K hr |
Environmental Specifications (at 25 ºC)
Operating Temperature at Full Load4 | N/A -20 to 50 ºC |
Non-Condensing Relative Operating Humidity |
N/A 20 to 90 % |
Storage Temperature |
N/A -40 to 85 ºC |
Non-Condensing Relative Storage Humidity |
N/A 10 to 95 % |
Temperature Drift (0 to 50 ºC) |
N/A < 0.03 %/ºC |
Vibration |
N/A 10 to 500 Hz, 2G 10 min/cycle, period of 60 min, each X, Y & Z axis |
EMC and Safety Specifications (at 25 ºC)
EMI Emissions |
N/A Compliance to EN55022, CISPR22 Class B (Conducted & Radiated) |
Harmonic Current |
N/A Compliance to EN61000-3-2, 3 |
EMS Immunity |
N/A Compliance to EN61000-4-2, 3-6, 8 & 11; EN55024 heavy, light industry level, criteria A |
Safety Approval |
N/A UL 60950-1, (Insulation Class -1) |
Note for EMC and Safety Specifications at 25 ºC |
N/A The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Specifications
RoHS Compliance |
N/A As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU. |
Industry Standards |
N/A CB CE MIL-HDBK-217F RoHS TUV UL |
- 1 Output voltage can be adjusted at VR51.
- 2 Ripple and noise are measured at 20 MHz of bandwidth by using a 12 Inch (in) twisted-pair wire termination with a 0.1 µF and 47 µF parallel capacitors.
- 3 Hiccup mode. Resets automatically once the fault condition is removed.
- 4 Refer to output load derating curve