ABU 125 Series - 125 Watt (W) Single Output Open Frame Switching Power Supplies
Power Supplies & LED Drivers
The ABU125 series is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive (TUV EN60950).
Single Output AC/DC Power Supply with PFC.
Unit of Measure
Items |
/Asset/a4193.jpg ABU125-050 4.75 to 5.25 Volt (V) Adjustable Output Voltage Range ABU 125 Series Switch Mode Power Supply |
/Asset/a4193.jpg ABU125-120 11.4 to 12.6 Volt (V) Adjustable Output Voltage Range ABU 125 Series Switch Mode Power Supply |
/Asset/a4193.jpg ABU125-150 14.3 to 15.7 Volt (V) Adjustable Output Voltage Range ABU 125 Series Switch Mode Power Supply |
/Asset/a4193.jpg ABU125-240 22.8 to 25.2 Volt (V) Adjustable Output Voltage Range ABU 125 Series Switch Mode Power Supply |
/Asset/a4193.jpg ABU125-270 25.7 to 28.3 Volt (V) Adjustable Output Voltage Range ABU 125 Series Switch Mode Power Supply |
|||||
Description | N/A The ABU125-050 is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive. | N/A The ABU125-120 is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive. | N/A The ABU125-150 is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive. | N/A The ABU125-240 is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive. | N/A The ABU125-270 is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive. | |||||
Click here to check stock >> | N/A | N/A | N/A | N/A | N/A | |||||
Alternating Current (AC) Input Voltage | N/A 90 to 264 V | |||||||||
Direct Current (DC) Input Voltage | N/A 127 to 373 V | |||||||||
Input Frequency Range | N/A 47 to 63 Hz | |||||||||
Input Current at 115 VAC (Root Mean Square (RMS)) | N/A 1.6 A | |||||||||
Input Current at Typical 230 VAC | N/A 0.8 A | |||||||||
Maximum Inrush Current at 115 VAC for Cold Start | N/A 30 A | |||||||||
Maximum Inrush Current at 230 VAC for Cold Start | N/A 60 A | |||||||||
Power Factor at 230 VAC for Full Load | N/A > 0.95 | |||||||||
Power Factor at 115 VAC for Full Load | N/A > 0.98 | |||||||||
Leakage Current at 240 VAC | N/A < 2.4 mA | |||||||||
Direct Current (DC) Output Voltage | N/A 5 V | N/A 12 V | N/A 15 V | N/A 24 V | N/A 27 V | |||||
Direct Current (DC) Voltage Tolerance | N/A ±2.0 % | |||||||||
Output Current (15 CFM Fan) | N/A 0 to 20 A | N/A 0 to 10.42 A | N/A 0 to 8.34 A | N/A 0 to 5.21 A | N/A 0 to 4.63 A | |||||
Output Current (Convection) | N/A 0 to 14 A | N/A 0 to 8.34 A | N/A 0 to 6.67 A | N/A 0 to 4.16 A | N/A 0 to 3.70 A | |||||
Output Power (15 CFM Fan) | N/A 100 W | N/A 125 W | N/A 125 W | N/A 125 W | N/A 125 W | |||||
Output Power (Convection) | N/A 70 W | N/A 100 W | N/A 100 W | N/A 100 W | N/A 100 W | |||||
Adjustable Output Voltage Range1 | N/A 4.75 to 5.25 V | N/A 11.4 to 12.6 V | N/A 14.3 to 15.7 V | N/A 22.8 to 25.2 V | N/A 25.7 to 28.3 V | |||||
Ripple and Noise Voltage at Peak to Peak2 | N/A 100 mV | N/A 100 mV | N/A 100 mV | N/A 120 mV | N/A 120 mV | |||||
Load Regulation | N/A ±1.0 % | |||||||||
Line Regulation | N/A ±0.5 % | |||||||||
Efficiency | N/A 79.0 % | N/A 86.0 % | N/A 86.0 % | N/A 87.0 % | N/A 87.0 % | |||||
Start-Up Time at 230 VAC for Full Load | N/A 1500 ms | |||||||||
Start-Up Time at 115 VAC for Full Load | N/A 3000 ms | |||||||||
Rise-Up Time at 230 VAC for Full Load | N/A 30 ms | |||||||||
Rise-Up Time at 115 VAC for Full Load | N/A 30 ms | |||||||||
Hold-Up Time at 230 VAC for Full Load | N/A 14 ms | |||||||||
Hold-Up Time at 115 VAC for Full Load | N/A 14 ms | |||||||||
Overcurrent Protection3 | N/A 22.0 to 30.0 A | N/A 11.55 to 15.75 A | N/A 9.24 to 12.6 A | N/A 5.72 to 7.8 A | N/A 5.06 to 6.9 A | |||||
Direct Current (DC) Over Voltage Protection | N/A 5.75 to 6.75 V | N/A 13.8 to 16.2 V | N/A 13.8 to 16.2 V | N/A 27.6 to 32.4 V | N/A 31.1 to 36.4 V | |||||
Output Type | N/A Constant Voltage | |||||||||
Length | N/A 127 mm5.00 in | |||||||||
Width | N/A 76.2 mm3.00 in | |||||||||
Height | N/A 27.0 mm1.05 in | |||||||||
Weight | N/A 300 g | |||||||||
Cooling | N/A Natural Convection or Fan at 15 CFM | |||||||||
Isolation Resistance at 500 VDC (Input (I/P) - Output (O/P)) | N/A 100 MO | |||||||||
Isolation Resistance at 500 VDC (Input (I/P) - Floating Gate (FG)) | N/A 100 MO | |||||||||
Isolation Resistance at 500 VDC (Output (O/P) - Floating Gate (FG)) | N/A 100 MO | |||||||||
Alternating Current (AC) Dielectric Strength (Input (I/P) - Output (O/P)) | N/A 3 kV | |||||||||
Alternating Current (AC) Dielectric Strength (Input (I/P) - Floating Gate (FG)) | N/A 1.5 kV | |||||||||
Alternating Current (AC) Dielectric Strength (Output (O/P) to Floating Gate (FG)) | N/A 0.5 kV | |||||||||
Warranty | N/A 3 years | |||||||||
Minimum Mean Time Between Failure (MTBF) per MIL-HDBK-217F (25 ºC) | N/A 200 K hr | |||||||||
Mean Time Between Failure (MTBF) per MIL-HDBK-217F (25 ºC) | N/A | |||||||||
Operating Temperature at Full Load4 | N/A -20 to 50 ºC | |||||||||
Operating Temperature5 | N/A | |||||||||
Non-Condensing Relative Operating Humidity | N/A 20 to 90 % | |||||||||
Storage Temperature | N/A -40 to 85 ºC | |||||||||
Non-Condensing Relative Storage Humidity | N/A 10 to 95 % | |||||||||
Temperature Drift (0 to 50 ºC) | N/A < 0.04 %/ºC | |||||||||
Vibration | N/A 10 to 500 Hz, 2G 10 min/cycle, period of 60 min, each X, Y & Z axis | |||||||||
EMI Emissions | N/A Compliance to EN55022, CISPR22 Class B (Conducted & Radiated) | |||||||||
Harmonic Current | N/A Compliance to EN61000-3-2, 3 | |||||||||
EMS Immunity | N/A Compliance to EN61000-4-2, 3-6, 8 & 11; EN55024 heavy, light industry level, criteria A | |||||||||
Safety Approval | N/A UL 60950-1, (Insulation Class -1) | |||||||||
Note for EMC and Safety Specifications at 25 ºC | N/A The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | |||||||||
RoHS Compliance | N/A As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU. | |||||||||
Industry Standards | N/A CB CE MIL-HDBK-217F RoHS TUV UL | |||||||||
Note |
N/A
|
|||||||||
|